Pillar molds
The FINNFOAM pillar mold was designed particularly for use as a casting mold and insulation for pillar foundations.
FINNFOAM pillar molds are made from F-300 strength class FINNFOAM (XPS) insulation material. Due to its fully consistent and closed cell structure, FINNFOAM is a durable, waterproof thermal insulation product. FINNFOAM is perfectly suited for use in structures that are subject to sustained load as frost insulation, for insulating base floors, or various supplementary thermal insulation applications.
Material: Extruded polystyrene
Color: Light yellow
TECHNICAL SPECIFICATIONS:
Panel |
Size (inner dimension) |
Thickness | |
Finnfoam Pillar mold | 500 x 500 x 285 mm | 50 mm | |
Finnfoam Pillar mold | 1000 x 1000 x 500 mm | 100 mm |
Pakkauskoko: 2 kpl/pkt
Pillar molds (50 mm)
- Dimensions
- Technical details
Value | Unit | According to EN 13164 | Standard | |
---|---|---|---|---|
Length | 500 x 500 x 285 | mm | ||
Thickness | 50 | mm |
Value | Unit | According to EN 13164 | Standard | |
---|---|---|---|---|
Thermal conductivity | EN 12667 | |||
λ Declared | 0,035 | [W/(m K)] | ||
λu, frost insulation | 0,037 | [W/(m K)] | ||
Compressive strength, short-term 45 days, ≥ 30mm | 250 | kPa | CS(10/Y)250 | EN 826 |
Compressive creep over 50 years | 130 | kPa | CC(2/1,5/50)130 | EN 1606 |
Design stability | < 5 | % | DS(70,90) | EN 1604 |
Water absorption when fully immersed in the long-term | ≤ 0,7 | t% | WL(T)0,7 | EN 12087 |
Freeze-thaw-resistance | ≤ 1 | t% | FTCD1 | EN 12091 |
Absorption of water by diffusion | ≤ 2 | t% | WD(V)2 | EN 12088 |
Water vapor permeability | 150 | μ | MU150 | EN ISO 10456 |
Capillarity | 0 | |||
Fire class | NPD | |||
Thermal expansion | 0,07 | [mm/(m K)] | ||
Service temperature | - 150... + 75 | C° | EN 14706 | |
Indoor air emission class | M1 |
Pillar molds (100 mm)
- Dimensions
- Technical details
Value | Unit | According to EN 13164 | Standard | |
---|---|---|---|---|
Length | 1000 x 1000 x 500 | mm | ||
Thickness | 100 | mm |
Value | Unit | According to EN 13164 | Standard | |
---|---|---|---|---|
Thermal conductivity | EN 12667 | |||
λ Declared | 0,036 | [W/(m K)] | ||
λu, frost insulation | 0,037-0,040 | [W/(m K)] | ||
Compressive strength, short-term 45 days, ≥ 30mm | 300 | kPa | CS(10/Y)300 | EN 826 |
Compressive creep over 50 years | 130 | kPa | CC(2,0/1,5/50)180 | EN 1606 |
Design stability | < 5 | % | DS(70,90) | EN 1604 |
Water absorption when fully immersed in the long-term | ≤ 0,7 | t% | WL(T)0,7 | EN 12087 |
Freeze-thaw-resistance | ≤ 1 | t% | FTCD1 | EN 12091 |
Absorption of water by diffusion | ≤ 1 | t% | WD(V)1 | EN 12088 |
Capillarity | 0 | |||
Fire class | NPD | EN 13501-1 | ||
Thermal expansion | 0,07 | [mm/(m K)] | ||
Service temperature | - 150... + 75 | C° | EN ISO 18097 |