Flat edge (FI)

Due to its fully consistent and closed cell structure, FINNFOAM (XPS) is a durable, waterproof thermal insulation product. FINNFOAM is excellently suited for use as frost insulation and for insulating base floors, walls, and ceilings. It is also perfect for various supplementary thermal insulation applications.

Material: Extruded polystyrene
Color: Light yellow
Method of fitting: Flat edge

TECHNICAL SPECIFICATIONS:

Panel Length Width Thickness
Flat edge, FI-300 2500 mm 600 mm 20–100 mm
Flat edge, FI-400 2500 mm 600 mm 30–300 mm
Flat edge, FI-500 2500 mm 600 mm 50–120 mm
Flat edge, FI-700 2500 mm 600 mm 50–120 mm

 

 

FI-300

  • Dimensions
  • Technical details
Value Unit According to EN 13164 Standard
Length 2500 mm EN 822
Width 600 mm EN 822
Thickness 20 - 100 mm EN 823
Value Unit According to EN 13164 Standard
Thermal conductivity EN 12667
λ Declared 0,034-0,038 [W/(m K)]
Arvot 40-80 mm paksulle levylle:
λu, dry structures 0,035 [W/(m K)]
λu, frost insulation 0,037 [W/(m K)]
λu, slab-on-ground foundation 0,036 [W/(m K)]
λu, inverted roof 0,037 [W/(m K)]
Compressive strength, short-term 45 days, 20 mm 200 kPa CS(10/Y)200 EN 826
Compressive strength, short-term 45 days, ≥ 30mm 250 kPa CS(10/Y)250 EN 826
Compressive creep over 50 years 130 kPa CC(2/1,5/50)130 EN 1606
Design stability < 5 % DS(70,90) EN 1604
Water absorption (FINNFOAM core) in long-term immersion ≤ 0,7 t% WL(T)0,7 EN 12087
Freeze-thaw-resistance ≤ 1 t% FTCD1 EN 12091
Absorption of water by diffusion ≤ 2 t% WD(V)2 EN 12088
Water vapor permeability 150 μ MU150 EN ISO 10456
Capillarity 0
Fire class NPD EN 13501-1
Thermal expansion 0,07 [mm/(m K)]
Service temperature when subject to load - 150... + 75 EN ISO 18097
Indoor air emission class M1

FI-400

  • Dimensions
  • Technical details
Value Unit According to EN 13164 Standard
Length 2500 mm EN 822
Width 600 mm EN 822
Thickness 30 - 300 mm EN 822
Value Unit According to EN 13164 Standard
Thermal conductivity EN 12667
λ Declared 0,035-0,038 [W/(m K)]
λu, dry structures 0,035-0,038 [W/(m K)]
λu, frost insulation 0,037-0,040 [W/(m K)]
λu, slab-on-ground foundation 0,036-0,039 [W/(m K)]
λu, inverted roof 0,037-0,040 [W/(m K)]
Compressive strength, short-term 45 days, ≥ 30mm 300 kPa CS(10/Y)300 EN 826
Compressive creep over 50 years 180 kPa CC(3,0/2,0/50)180 EN 1606
Design stability < 5 % DS(70,90) EN 1604
Water absorption when fully immersed in the long-term ≤ 0,7 t% WL(T)0,7 EN 12087
Freeze-thaw-resistance ≤ 1 t% FTCD1 EN 12091
Absorption of water by diffusion ≤ 2 t% WD(V)2 EN 12088
Water vapor permeability 150 μ MU150 EN ISO 10456
Capillarity 0
Fire class NPD
Thermal expansion 0,07 [mm/(m K)]
Service temperature - 150... + 75 EN ISO 18097
Indoor air emission class M1

FI-500 (EN)

  • Dimensions
  • Technical details
Value Unit According to EN 13164 Standard
Length 600 mm EN 822
Width 2500 mm EN 822
Thickness 50 - 120 mm EN 823
Value Unit According to EN 13164 Standard
Thermal conductivity EN 12667
λ Declared 0,037-0,039
λu, dry structures 0,037-0,039 [W/(m K)]
λu, frost insulation 0,039-0,041 [W/(m K)]
λu, slab-on-ground foundation 0,038-0,040 [W/(m K)]
λu, inverted roof 0,039-0,041 [W/(m K)]
Compressive strength, short-term 45 days, ≥ 30mm 400 kPa CS(10/Y)400 EN 826
Compressive creep over 50 years 210 kPa CC(3,0/2,0/50)210 EN 1606
Design stability < 5 % DS(70,90) EN 1604
Water absorption when fully immersed in the long-term ≤ 0,7 t% WL(T)0,7 EN 12087
Freeze-thaw-resistance ≤ 1 t% FTCD1 EN 12091
Absorption of water by diffusion ≤ 2 t% WD(V)2 EN 12088
Water vapor permeability 150 μ MU150 EN ISO 10456
Capillarity 0
Fire class NPD EN 13501-1
Thermal expansion 0,07 [mm/(m K)]
Service temperature - 150... + 75 EN ISO 18097
Indoor air emission class M1

FI-700

  • Dimensions
  • Technical details
Value Unit According to EN 13164 Standard
Length 600 EN 822
Width 2500 EN 822
Thickness 50 - 120 EN 823
Value Unit According to EN 13164 Standard
Thermal conductivity EN 12667
λ Declared 0,037-0,038 [W/(m K)]
λu, dry structures 0,037-0,038 [W/(m K)]
λu, frost insulation s 0,039-0,040 [W/(m K)]
λu, slab-on-ground foundation 0,038-0,039 [W/(m K)]
λu, inverted roof 0,039-0,040 [W/(m K)]
Compressive strength, short-term 45 days, ≥ 30mm 600 kPa CS(10/Y)600 EN 826
Compressive creep over 50 years 270 kPa CC(3,0/2,0/50)270 EN 1606
Design stability < 5 % DS(70,90) EN 1604
Water absorption when fully immersed in the long-term ≤ 0,7 t% WL(T)0,7 EN 12087
Freeze-thaw-resistance ≤ 1 t% FTCD1 EN 12091
Absorption of water by diffusion ≤ 2 t% WD(V)2 EN 12088
Water vapor permeability 150 μ MU150 EN ISO 10456
Capillarity 0
Fire class NPD EN 13501-1
Thermal expansion 0,07 [mm/(m K)]
Service temperature - 150... + 75 EN ISO 18097
Indoor air emission class M1